Piezo Material Properties

 
PROPERTY UNIT SYMBOL SM111 SM112 SM118 SM121 SM211 SM311 SM410 SM411 SM422 SM412 SM510 SM511 SM512 SM701 SM702
EQUIVALENCE Modif.
PZT-4
N/A PZT-8 PZT-4 N/A PZT-5H PZT-5J PZT-5J Modif.
PZT-5
PZT-5A Modif.
PZT-5
BaTiO3 N\A Actuators Acoustic Wave
Modif.
Navy Type I
N/A Navy Type III Navy Type I N/A Navy Type VI Navy Type V Navy Type V N/A Navy Type II N/A BaTiO3 N\A N/A N/A
OLD SYMBOLS . . . . . . . . . . . . .    .
Electromechanical
coupling coefficient
  Kp 0.58 0.59 0.51 0.54 0.67 0.65 0.64 0.64 0.64 0.63 0.65 0.34 0.60 0.65 0.06
Kt 0.45 0.46 0.40 0.43 0.35 0.37 0.45 0.45 0.48 0.42 0.50 0.32 0.50   0.49
K31 0.34 0.35 0.30 0.32 0.41 0.38 0.36 0.37 0.36 0.35 0.38 0.196 0.35 0.38  
Frequency constant Hz ● m Np 2200 2150 2340 2290 1940 1980 2030 2060 1990 2080 2000     1900  
Nt 2070 2050 2090 2080 1920 1950 2050 2000 2040 2080 2250     1900 2200
N31 1680 1600 1700 1690 1410 1450 1460 1500 1460 1560          
Piezoelectric constant ×10-12m/v d33 320 360 250 300 650 600 500 500 500 450 450 160 400 640 50
d31 -140 -155 -100 -130 -320 -270 -210 -210 -210 -190 -210 30 170 -410  
×10-3Vm/N g33 25 24.7 25.6 26.4 13.6 19.4 23.3 24.2 23.3 25.6   14.3 28 16  
g31 -11.0 -10.6 -12.5 -12.9 -6.7 -9.2 -10.3 -10.4 -10.3 -12.6   5.4 12    
Elastic Constant ×1010N/m2 Y33 7.3 7.2 7.4 7.3 5.1 5.3 5.6 5.4 5.6 5.6   119      
Y11 8.6 8.4 8.7 8.6 6.2 7.2 6.5 7.4 6.5 7.6     16.6    
Mechanical Quality Factor ----- Qm 1800 1600 1200 1000 60 80 60 85 60 100 70 1200 85 65 800
Dielectric Constant @1KHz eT33/e 0 1400 1600 1100 1300 5400 3500 2000 2100 2200 1850 2100 1260 1600 3800 250
Dissipation Factor %@1KHz tan δ 0.4 0.6 0.2 0.4 3.0 2.5 2.0 2.0 2.0 1.2 2 0.5 2.0 0.4 1.5
Curie Temperature °C Tc 320 320 300 320 165 220 320 320 290 320 260 115 350 180 250
Density g/cm3 r 7.9 7.9 7.6 7.8 7.8 7.8 7.7 7.8 7.7 7.8 7.45 5.6 7.6 7.8 6.9

 

SUGGESTION FOR SOLDERING WIRE LEADS TO OUR CERAMICS: 
The average Curie temperature for our Piezo ceramics is around 250°C. For soldering small items, the soldering method we suggest is: use at least 2% Silver content solder material, and the soldering temperature should be 250°C-270°C within 2 seconds. Longer than that it may cause the transducer to loose its Piezoelectric properties as well cause the Silver electrode to peel off.
We offer a Lead free solder material that can be found HERE

* All measurements made according to IEEE standard on piezoelectricity, 176-1987